8 Secure Lock To Door
1. Feed wire and connector:
• For wood door, feed connectors and wires through the door
and up the wire run channel (Fig. 8A).
• For metal door (not shown), feed connectors and wires into
the lockbody hole and out the controller hole.
2. Position ground lug between (top) #10-32x1-1/4" through-bolt
and rose assembly (Fig. 8A).
NOTE: Proper placement of ground wire (Fig. 8A, B) will prevent
pinching/damage to the ground wire.
3. Secure rose assembly with (2) #10-32x1-1/4" through-bolts.
4. Secure latch by fully tightening (2) #6 x 3/4" self-tapping screws
(refer to previous section 3 - Install Latchbolt).
NOTE: Cable lengths exaggerated for illustrative purposes.
Ground
Wire
9 Assemble Inside Trim
1. Verify spacer bushing is inserted horizontally and
aligned with lever (Fig. 9).
2. Place rose over shaft of lock body against the
surface of the door; hand-tighten, turning clockwise.
3. Attach lever. Push until engaged.
Fig. 8B Detail
Fig. 9
1-800-810-WIRE • www.sargentlock.com • A8203A
Inside of
Door
Fig. 8A
Inside of Door
Rose
Inside lever