Speed Analog 3 Wire Connection - Baldor ID15J1F50-ER Installation And Operating Manual

Inverter control. 15j series
Table of Contents

Advertisement

3 Speed Analog 3 Wire Connection

Figure 3-17 3 Speed Analog 3 Wire Connection Diagram
Function
ANA CMD Select
Speed 1
Preset
Speed 2
Preset
Speed 3
Preset
J4-11
Momentary CLOSED starts Forward motor rotation.
J4-12
Momentary CLOSED starts Reverse motor rotation.
J4-13
Momentary OPEN motor decels to stop (depending on Keypad Stop mode).
J4-14
Selects preset speeds as defined in Table 3-12.
J4-15
Selects preset speeds as defined in Table 3-12.
J4-16
OPEN selects direction commands from Keypad.
CLOSED selects direction commands from terminal strip.
J4-17
OPEN selects speed commanded from Keypad.
CLOSED selects terminal strip speed source (selected in the Level 1 Input block,
ANA CMD Select parameter).
MN715J
Table 3-12
Speed Select 1
Open
Closed
Closed
Open
Speed Select 2
Open
Open
Closed
Closed
Receiving and Installation 3-23