Power-Up Procedure - Baldor ID15J1F50-ER Installation And Operating Manual

Inverter control. 15j series
Table of Contents

Advertisement

WARNING:
Make sure that unexpected operation of the motor shaft during start
up will not cause injury to personnel or damage to equipment.

Power-up Procedure

1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Select and program additional parameters to suit your application.
The control is now ready for use in keypad mode. The terminal strip wiring
may be changed and different parameter values used for another operating
mode.
1-2 Quick Start
Turn power on. Be sure no faults are displayed on the keypad display.
Set the Level 1 Input block, Operating Mode to "Keypad".
Set the Level 2 Output Limits block, "MIN Output FREQ" parameter.
Set the Level 2 Output Limits block, "MAX Output FREQ" parameter.
If the desired peak current limit setting is not correct, set the Level 2
Output Limits block, "PK Current Limit" parameter as desired.
Enter the following motor data in the Level 2 Motor Data block
parameters:
Motor Rated Amps (FLA)
Motor Rated Speed (base speed)
Motor Rated Frequency (Nameplate)
If External Dynamic Brake hardware is used, set the Level 2 Brake
Adjust block parameters as desired.
Set the Level 1 V/HZ Boost block, "V/HZ Profile" parameter for the
correct V/Hz ratio for your application.
If the load is a high initial starting torque type, the torque boost and accel
time may need to be increased. Set the Level 1 V/HZ Boost block,
"Torque Boost" and the Level 1 Accel/Decel Rate block, "Accel Time #1"
as required.
MN715J