Mechanical Installation

4 Mechanical Installation

4.1 Items Supplied

Items supplied can vary according to product configu-
ration.
4
4
Make sure the items supplied and the information
on the nameplate correspond to the order confir-
mation. Illustration 4.1 and Illustration 4.2 show
sample nameplates for a D-sized drive either with
or without an options cabinet.
Check the packaging and the drive visually for
damage caused by inappropriate handling during
shipment. File any claim for damage with the
carrier. Retain damaged parts for clarification.
VLT
1
T/C: FC-202N110T4E20H2TGC7XXSXXXXAQBXCXXXXD0
2
P/N: 136G7653
3
90 kW / 125 HP, High Overload
4
IN: 3x380-480V 50/60Hz 171/154 A
5
OUT: 3x0-Vin 0-590Hz 177/160 A
110kW / 150 HP, Normal Overload
IN: 3x380-480V 50/60Hz 204/183 A
OUT: 3x0-Vin 0-590Hz 212/190 A
CHASSIS / IP20 Tamb. 40° C/104° F
Max Tamb. 55° C/131° F w/ Output Current Derating
SCCR 100 kA at UL Voltage range 380-480 V
6
1
Type code
2
Part number and serial number
3
Power rating
4
Input voltage, frequency, and current
5
Output voltage, frequency, and current
6
Discharge time
Illustration 4.1 Example Nameplate for Drive Only (D1h–D4h)
16
VLT® AQUA Drive FC 202
AQUA Drive
R
www.danfoss.com
S/N: 123456H123
ASSEMBLED IN USA
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-480 V
Danfoss A/S
6430 Nordborg
Denmark
089
CAUTION - ATTENTION:
See manual for special condition / mains fuse
`
Voir manuel de conditions speciales / fusibles
WARNING - AVERTISSEMENT:
Stored charge, wait 20 min.
Charge residuelle, attendez 20 min.
`
Danfoss A/S © 09/2018 All rights reserved.
VLT
AQUA Drive
R
www.danfoss.com
1
T/C: FC-202N200T4E5MH2XJC3XXSXXXXAXBXCXXXXDX
S/N: 123456H123
2
P/N: 136G7973
Use the following Typecode to order Drive-only replacement:
T/C: FC-202N200T4E5MH2XJC7XXSXXXXAXBXCXXXXDX
3
160 kW / 250 HP, High Overload
4
IN: 3x380-480V 50/60Hz 304/291 A
5
OUT: 3x0-Vin 0-590Hz 315/302 A
200 kW / 300 HP, Normal Overload
IN: 3x380-480V 50/60Hz 381/348 A
OUT: 3x0-Vin 0-590Hz 395/361 A
Type 12 / IP54 Tamb. 40° C/104° F
Max Tamb. 55 ° C/131° F w/ Output Current Derating
SCCR 100 kA at UL Voltage range 380-480 V
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-480 V
CAUTION - ATTENTION:
See manual for special condition / mains fuse
Voir manuel de conditions speciales / fusibles
WARNING - AVERTISSEMENT:
6
Stored charge, wait 20 min.
Charge residuelle, attendez 20 min.
`
1
Type code
2
Part number and serial number
3
Power rating
4
Input voltage, frequency, and current
5
Output voltage, frequency, and current
6
Discharge time
Illustration 4.2 Example Nameplate for Drive with Options
Cabinet (D5h-D8h)
NOTICE
LOSS OF WARRANTY
Do not remove the nameplate from the drive. Removing
the nameplate can result in loss of warranty.
ASSEMBLED IN USA
Danfoss A/S
6430 Nordborg
Denmark
`
MG21A502