Specifications
®
VLT
AQUA Drive FC 202
High/normal overload
(High overload=150% current during 60 s.
Normal overload=110% current during 60 s)
Typical shaft output at 525 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 525 V) [A]
Intermittent (60 s overload) (at 525 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [A]
Continuous kVA (at 525 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 525 V) [A]
Continuous (at 575/690 V)
Maximum number and size of cables per phase
- Mains, motor, brake, and load share [mm
Maximum external mains fuses [A]
Estimated power loss at 575 V [W]
Estimated power loss at 690 V [W]
3)
Efficiency
Output frequency [Hz]
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
Table 10.8 Electrical Data for Enclosures D2h/D4h/D7h/D8h, Mains Supply 3x525–690 V AC
1) For fuse ratings, see chapter 10.7 Fuses and Circuit Breakers.
2) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies to
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/vltenergyefficiency. Options and
customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add only 4 W.
3) Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy
efficiency class, see chapter 10.4 Ambient Conditions. For part load losses, see www.danfoss.com/vltenergyefficiency.
MG21A502
Operating Guide
2
(AWG)]
1)
2), 3)
2), 3)
Danfoss A/S © 09/2018 All rights reserved.
N315
HO
NO
200
250
300
350
250
315
D2h/D4h/D7h/D8h
303
360
455
396
290
344
435
378
276
327
289
343
347
411
292
347
279
332
2x185 (2x400)
550
3642
4465
3771
4614
0.98
0–590
110 (230)
80 (176)
± 15% (tolerance relates to variety in voltage and cable conditions). These
N400
HO
NO
250
315
350
400
315
400
360
418
540
460
344
400
516
440
327
380
343
398
411
478
347
403
332
385
2x185 (2x400)
550
4146
5028
4258
5155
0.98
10
0–590
110 (230)
80 (176)
105
10