Program 221: Charge Nicd Battery Hawker - Nortec UL60 Operation Manual

Battery charger /analyzer. 0.5 - 40vdc / 0.5 - 60a
Table of Contents

Advertisement

9 Tabular overview of the program procedures
9.3.8

Program 221: Charge NiCd battery HAWKER

Name according to manual: IUI charge - method
21: NiCd battery HAWKER
select Batteryprocessing:
P2: Charge
Enter:
Number of cells
Rated capacity
Step 1:
Charging with C
until a charging voltage of 1.55 V × number of cells is reached.
1
Step 2:
Topping charge C
for 2 hours.
5
In case no automatic cell tester is connected:
15 minutes before the end of the topping charge a signal asks for the measurement of the single cells
voltages and to control the electrolyte level.
Otherwise:
15 minutes before the end of the topping charge you are requested to control the electrolyte level.
End of program
Example:
Connected is a 24 V battery with 40 Ah.
The battery will be charged with 40 A to 31 V.
Afterwards the battery will be charged with 8 A for another 2 hours.
Time monitoring:
Charging maximum 90 minutes.
Voltage monitoring:
Monitoring minus ΔU > 30mV/cell during charging, error message:
minus delta U detected