9 Tabular overview of the program procedures

9.2 Initial commissioning

9.2.1

Program 110: Initial commissioning Pb battery sealed MIL

10: Pb battery sealed MIL
select Batteryprocessing:
P1: Initial commissioning
Enter:
Number of cells
Rated capacity
Step 1:
In case voltage is < 1.5 V for each cell the message is as follows:
U<1.5 V: select program 410
Otherwise:
Discharging with C
until a voltage of 1.5 V for each cell is reached.
5
Step 2:
I-charge with 0.4 C
1
Step 3:
U-charge with 2.4 V × number of cells until charging current decreased to 0.02 C
End of program
Time monitoring:
I- and U-charge maximum for 8 hours, capacity maximum1.5 × C
In case charged capacity is < 0.9 C: failure message: CAPACITY TOO LOW
58
until a charging voltage of 2.4 V × number of cells is reached.