9 Tabular overview of the program procedures
9.7.3

Program 623: Deep Discharge NiCd battery NKBN

Name according to manual: Re-Discharge for НКБН
23: NiCd battery NKBN
select Batteryprocessing:
P6: Deep Discharge
Enter:
Number of cells
Rated capacity
Step 1:
Discharging with C
until a voltage of 1 V for each cell is reached.
1
In case no automatic cell tester is connected:
If voltages are 23 V, 22 V and 21 V a signal requests the measurement of the single cells voltages.
Otherwise: cell measurement is done automatically
Afterwards discharging with C
End of program
Example:
Connected is a 24 V battery with 40 Ah.
The battery is discharged with 40 A to 20 V.
Time monitoring:
Discharging maximum 90 minutes.