Program 621: Deep Discharge Nicd Battery Hawker - Nortec UL60 Operation Manual

Battery charger /analyzer. 0.5 - 40vdc / 0.5 - 60a
Table of Contents

Advertisement

9 Tabular overview of the program procedures
9.7.1

Program 621: Deep Discharge NiCd battery HAWKER

Name according to manual: Deep Discharge with Cell shorting for HAWKER with C
21: NiCd battery HAWKER
select Batteryprocessing:
P6: Deep Discharge
Enter:
Number of cells
Rated capacity
Step 1:
Discharging with C
until a voltage of 1 V for each cell is reached.
1
In case no automatic cell tester is connected:
After 48 minutes a signal requests the measurement of the single cells voltages.
Otherwise: Cell measurement takes place automatically
Continue with discharging with C
cells is reached.
Step 2:
Afterwards discharging with C
The connection of an automatic cell scan adapter is required
Step 3:
Deep discharging with device integrated 1 Ohm resistors over each cell for 24 hours.
End of program
Example:
Connected is a 24 V battery with mit 40 Ah.
The battery at first will be discharged with 40 A to 20 V. Afterwards discharging with 4 A to 10 V.
After that 1 Ohm resistors will be shifted over the cells.
Time monitoring:
Discharging with C
maximum 90 minutes, discharging with C
1
© Nortec Electronics 2018
until the voltage of 1 V multiplied by the number of interconnected
1
until a voltage of 0.5 V for each cell is reached.
10
maximum 180 minutes.
10
Deep Discharge
1
107