9 Tabular overview of the program procedures
9.9 Constant Voltage Supply
9.9.1
Program 800: Constant Voltage Supply
00: Other battery
select Batteryprocessing:
P8: Constant Voltage Supply
Enter:
Charging current
Nominal voltage
Step 1:
Constant voltage supply with input voltage and input current.
Time: 24 hours
End of program
9.9.2
Program 810: Constant Voltage Supply Pb battery sealed MIL
9.9.3
Program 811: Constant Voltage Supply Pb battery sealed commercial
9.9.4
Program 816: Constant Voltage Supply Pb battery vented commercial
9.9.5
Program 819: Constant Voltage Supply Pb battery (free input)
10: Pb battery sealed MIL
select Batteryprocessing:
P8: Constant Voltage Supply
Enter:
Charging current
Nominal voltage
Step 1:
Constant voltage supply with 2.25 V for each cell and with the input current.
Time: 24 hours
End of program
© Nortec Electronics 2018
Constant Voltage Supply
115