Program 722: Reconditioning Nicd Battery Saft - Nortec UL60 Operation Manual

Battery charger /analyzer. 0.5 - 40vdc / 0.5 - 60a
Table of Contents

Advertisement

9 Tabular overview of the program procedures
9.8.3

Program 722: Reconditioning NiCd battery SAFT

Name according to manual: Deep Discharge, Cell shorting and Charge
22: NiCd battery SAFT
select Batteryprocessing:
P7: Reconditioning
Enter:
Number of cells
Rated capacity
Waiting after program step "Deep Discharge"? (see step 4)
Step 1:
Discharging with C
until a voltage of 1 V for each cell is reached.
1
Step 2:
Afterwards discharging with C
Step 3:
Deep discharging with device integrated 1 Ohm resistors over each cell for 12 hours.
Step 4:
D
epending on settings the device might wait after executing Step 4. This will prevent, that e.g. in the
night the request to control the electrolyte level might occur.
Charging with C
until the charging voltage of 1.57 V × number of cells is reached.
1
Step 5:
Topping charge C
for 4 hours.
10
30 minutes before the end of the topping charge you are asked to control the electrolyte level
End of program
Time monitoring:
Discharging with C
maximum 90 minutes, discharging with C
1
© Nortec Electronics 2018
until a voltage of 0.5 V for each cell is reached.
10
maximum 180 minutes.
10
113