8 Program selection
8.4.3

Work with lead batteries

All battery types starting with 1x respond. In particular, these are:
Type 10:
Type 11:
Type 12:
Type 16:
Type 17:
Type 19:
Choose the type using the following keys
and confirm with pressing the key
For example, select the charging of a military sealed lead battery:
Use this key
to get to the desired kind of treatment and confirm by pressing the key
On dispay you will see:
10: Pb battery sealed MIL
P410:  Please enter parameter:
RATED VOLTAGE:
Enter the nominal voltage of the battery. You find it on the identification plate of the battery.
NOTE:
Lead batteries usually consist of several cells of 2 V each.
Commercially common:
V
2
cells
V
6
batteries
V
12
batteries
V
24
batteries
The device only accepts 2.0 V and the multiple. All other entry will be rejected as defective.
Confirm the entered voltage by pressing
© Nortec Electronics 2018
Lead acid battery sealed MIL
Lead acid battery sealed commercial
Valve regulated lead acid aircraft battery
Lead acid battery vented commercial
Lead acid battery MIL P3-C Orion
Lead acid battery (free input)
afterwards select kind of treatment.
00.00 V
. The display shows:
Battery data entry