Program 420 Step 5 - Nortec UL60 Operation Manual

Battery charger /analyzer. 0.5 - 40vdc / 0.5 - 60a
Table of Contents

Advertisement

8 Program selection
8.5.5

Program 420 Step 5

NiCd battery (manufacturer independent)
Program:
Maintenance
1
P420:S5: I-CHARGE 2
30.98V
2
5
1
Program number
Kind of treatment
Battery type
2
Step number
3
Step type
4
00:34:38
5
30.98 V
6
4.0 A
7
4.00 Ah
8
0060 MIN
© Nortec Electronics 2018
04.00A
04.00Ah
6
3
060MIN
7
4 = Maintenance
20 = NiCd battery (manufacturer independent)
= S5
= I-CHARGE 2
= present time
= present battery voltage
= present charging current
The charging current with the test program for
NiCd batteries is chosen in a way that the
capacity is charged again within 1 h.
4 A if a 4 Ah battery is in use.
Capacity loaded in 60 minutes in Ah.
Display of charging time with positive sign
(forward count).
The display screen for program 420
16.01.15 00:34:38
--.-°C
8
4
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents