Program 210: Charge Pb Battery Sealed Mil - Nortec UL60 Operation Manual

Battery charger /analyzer. 0.5 - 40vdc / 0.5 - 60a
Table of Contents

Advertisement

9 Tabular overview of the program procedures
9.3.1

Program 210: Charge Pb battery sealed MIL

10: Pb battery sealed MIL
select Batteryprocessing:
P2: Charge
Enter:
Nominal voltage
Rated capacity
Step 1:
In case the battery voltage before starting charging is below 2.15 V × numbers of cells:
Precharging with 2.4 V × number of cells until charging current of 0.4 C
This step will not be printed if it takes less than 3 minutes.
Step 2:
I-charge with 0.4 C
1
Step 3:
U-charge with 2.4 V × number of cells until the charging current is decreased to 0.02 C
End of program
Time monitoring:
Precharge maxiumum 2 hours, I- and U-charge maximum 8 hours, capacity maximum 1.5 × C
66
until a charging voltage of 2.4 V × number of cells is reached.
is reached.