Battery charger /analyzer. 0.5 - 40vdc / 0.5 - 60a
Table of Contents

Advertisement

The device is protected against polarity reversal or polarity reversal of the battery. In the event of
reversed connection of the charging cable, the device signals "voltage <0.1 V" and requests to
stop the program. After removal of the fault, the program must be restarted.
Generally, the valve plugs must be removed beforehand the electrical maintenance. The foregoing
applies to working with automatic cell testers. The valve plugs can not be removed lateron with
with mounted adapter.
The cover from sealed aircraft batteries have always to remove beforehand.
Take utmost care when entering the battery data, charging parameters and the number of cells of
NiCd batteries. Incorrect entries may damage the battery.
The programs of the battery charger / analyzer UL60 were created with the utmost care accord-
ing to the maintenance manuals of the battery manufacturers, but are offered without guaran-
tee. Before applying the programmed programs, they must be checked for compliance with
currently valid maintenance manuals of the battery manufacturer. In any doubt or in case of
deviations the currently valid maintenance manual of the battery manufacturer always applies.
We ask you to inform us in any case of any discrepancies.
Working with batteries:
When used properly and according to the manufacturer's instructions from batteries do not pose
any particular risks.
Never use the device for maintenance of NiCd and lead-acid batteries without chemical neu-
tralization between operational or use different cable sets.
The currently valid maintenance manuals and safety regulations of the respective battery
manufacturer must be strictly followed and shall give priority to the safety instructions de-
scribed here.
Note maintenance and safety instructions of the battery manufacturer!
Wear protective clothing and eye protection for all works on batteries!
Avoid contact of acid with skin or eyes!
© Nortec Electronics 2018
-
All maintenance on batteries exclusively carried out by properly
qualified personnel.
-
Observe the applicable accident prevention regulations.
-
In case of emergency rinse immediately with plenty of water.
-
Then call a doctor immediately.