Filtec FT-70c Service And Technical Reference Manual page 48

Fill level inspector, for can inspection
Table of Contents

Advertisement

Industrial Dynamics Company, Ltd. © Form 40256-0600
2. Cut the vertical support pipe to the calculated length (L
removing the excess from the end that is not flanged.
1
No.
1
2
Figure 3-4. Removing the excess from the vertical support pipe.
3. Assemble the mounting base tripod. Leave the bolts loose
enough to slide the vertical support pipe inside.
Figure 3-5. Assembling the mounting base tripod.
Chapter 3: Installing the FT-70
Description
Remove excess from this end.
Flanged end
),
p
2
3-9