Filtec FT-70c Service And Technical Reference Manual page 103

Fill level inspector, for can inspection
Table of Contents

Advertisement

FT-70 Fill Level Inspector Service Manual
Function Group
Counters Key 3
3
Rejector Key 4
4
5-8
Function Name
°
Width At Down Can
°
Height of Can
°
Dia. Missing Lid Width
°
Minimum Dia. Missing Lid
*
Total Throughput
*
Total Rejects
*
Total Underfill
*
Total Overfill
*
Total Missing Lid
*
Total Bulged End
*
Total Down Can
*
Total Dia. Missing Lid
*
Total External Reject
*
Reset All Counters
°
Reset Total Throughput
°
Reset Total Rejects
°
Reset Underfill
°
Reset Overfill
°
Reset Missing Lid
°
Reset Bulged End
°
Reset Down Can
°
Reset Dia. Missing Lid
°
Reset External Reject
*
Rejector Status
*
Fire Rejector On Demand
°
Rejector Pulse Width
°
Reject Next Container
°
Inspect Trig To C/l Rej
Rejector Reaction Delay
Parameter
1-250 mm
1-250 mm
1-65,000 Pulses:
Updating Constantly
Updating Last Reject
1-65,000 Pulses
0-99,999,999
0-99,999,999
0-99,999,999
0-99,999,999
0-99,999,999
0-99,999,999
0-99,999,999
0-99,999,999
0-99,999,999
Execute
Execute
Execute
Execute
Execute
Execute
Execute
Execute
Execute
Execute
On /Off
Execute
0-250 ms
1-299
1-300 mm
1-150
Industrial Dynamics Company, Ltd. © 40256-0600
Default
79 mm
125 mm
Updating Constantly
55 Pulses
Off
Off
22 ms
0
500 mm
20 ms