Executing The Fill Level Optimization Routine; Establishing The Underfill X-Ray Threshold - Filtec FT-70c Service And Technical Reference Manual

Fill level inspector, for can inspection
Table of Contents

Advertisement

FT-70 Fill Level Inspector Service Manual

Executing the Fill Level Optimization Routine

Note
6-38
The optimization routine steps you through the following options.
All options are contained under Key 1 while in the Calibrate Mode.
• Fill Level Optimization
• Learn Target Head Height
• Dyn Reject Pt Test
• Dyn Prod Good Test
• Review Fill Level Test
You can abort the optimization routine at any point in the process
by pressing Key 6.
Establishing the Underfill X-ray Threshold
1. Press Key 5 until SYSTEM DISPLAY appears and then press
the Arrow Key to enter the Calibrate Mode. If your system is
password protected, you must enter the password before you
are allowed to enter the Calibrate Mode.
2. Press Key 1 until FILL LEVEL OPTIMIZATION appears and
then press the Arrow Key to begin determining the Gamma
Threshold for the container.
3. Precisely center a 100 percent reject container in the inspection
tunnel and then press any key to continue.
4. Lower the x-ray beam into the liquid by slowly turning the
Head Height Adjustment Crank. The head height should be
lowered well below the liquid level.
5. Press the Arrow Key and the Static Full x-ray count is
displayed. This is the average of 128 samples.
6. When ready to continue press the Arrow Key.
7. Use the Head Height Crank to raise the x-ray beam above the
liquid level as much as possible while keeping it below the
container lid.
8. Press the Arrow Key and the Static Empty x-ray count is
displayed. This is the average of 128 samples.
9. When ready to continue press the Arrow Key.
Industrial Dynamics Company, Ltd. © 40256-0600

Advertisement

Table of Contents
loading