Replacing The Rejector Pad - Filtec FT-70c Service And Technical Reference Manual

Fill level inspector, for can inspection
Table of Contents

Advertisement

Warning
Industrial Dynamics Company, Ltd. © Form 40256-0600

Replacing the Rejector Pad

The actual lifespan of the rejector pad depends upon the operating
conditions of your production line. Inspect the pad weekly and
replace if worn, cracked, or hardened.
Turn off all power to your system before attempting any repair
procedure. See Before You Perform Any Maintenance Procedure, at
the beginning of this section.
1. Power down the rejector.
2. Remove the retaining screw and washer on the top of the
rejector shoe.
3.
Slide the pad up to remove it from the shoe.
4. Insert the new pad by sliding it onto the shoe. Be sure the notch
in the pad backing is positioned at the bottom.
5. Replace the retaining screw and washer.
6. Power up the rejector.
Chapter 7: Maintenance Procedures
7-7