FT-70 Fill Level Inspector Service Manual
Dip Switch Pack S2
10-6
S2-1: Baud Rate
Defines the baud rate (bits per second) for the user serial port
(RS-422/423) as either 1200 or 9600. The default is 1200 baud.
S2-2: Handshake Flags
Enables the use of the Serial Hardware Handshake lines. The
default is off.
S2-3: Parity On/Off
Enables the parity bit in the Serial Data transmission. The default is
off.
S2-4: Parity Odd/Even
Allows selection of odd or even parity when S2-3 is open. The
default is odd.
S2-5: Character Size
Allows selection of 7 or 8 bit characters. The default is 8 bit.
S2-6: Multi-Serial
Enables the FT-70 for a multiple unit serial network and switches
the serial port from active open to tri-state, RS-485. The default is
RS-485.
S2-7: Led Section Selector
Defines current LED section. The default is section 1.
S2-8: Led Bank Selector
Defines current logical LED bank. The default is bank 1.