EVO S - Installation and Servicing
3.4. Conditions of use
Maximum start setting temperature
Safety temperature
Maximum service pressure
Minimum cold pressure
Nominal water flow rate (to P/20)
Minimal water flow rate (to P/25)
Water content
Weight without water
Temperature of installation room (min. /
max.)
Relative humidity of installation room
Protection level
Maximum altitude of installation
3.5. Electrical connection
Electrical supply
Electrical power consumption at Qn
(without accessories)
Electrical power consumption at Qn (with
accessories)
Electrical power consumption in standby
mode
Max length of sensor cables
Power terminal output
18 / 136
50
70
°C
°C
hPa
(bar)
hPa
(bar)
m
/h
2,4
3,0
3
m
/h
1,9
2,4
3
l
5
9
kg
60
90
°C
between 5% and 95%
m
50
70
V
230 V AC (+10% -15%), 50Hz
138
96
W
W
192
135
W
External sensor: 40 in 0.5 mm² (120 in 1.5 mm²)
m
Ambient thermostat: 200 in 1.5 mm²
Ambient sensor: 200 in 1.5 mm²
230V AC (+10%, -15%)
V
A
EVO S
95
115
85
105
4000
(4)
1000
(1)
4,1
5,1
3,3
4,1
10,2
12,8
95
100
5 / 45
IP24D
2000
MODELS
95
115
160
206
274
348
3
DHW sensor: 10
5 mA - 1A
00RNO0333-B (U0625869)
135
5,8
4,7
15,3
125
135
263
403