IDEAL EVO S 50 Installation And Servicing page 132

Table of Contents

Advertisement

EVO S - Installation and Servicing
Line
Programming
No.
8790
Heating circuit pump 3
8791
HC mixing valve 3 open
8792
HC mixing valve 3 closed
8795
Speed heating circuit pump 3
8800
Room temp 3
8801
Room setpoint 3
8803
Flow temp 3
8804
Flow temp setpoint 3
8809
Room thermostat 3
8820
DHW pump
8825
Speed DHW pump
8826
Speed DHW interm circ pump
8827
Speed inst DHW heater pump
8830
DHW temp 1
8831
DHW temp setpoint
8832
DHW temp 2
8835
DHW circulation temp
8836
DHW charging temp
8852
DHW consumption temp
8853
Instant WH setpoint
8860
DHW flow
8875
Flow temp setp VK1
8885
Flow temp setp VK2
8895
Flow temp setp swimming pool
8900
Swimming pool temp
8901
Swimming pool setpoint
8930
Primary controller temp
8931
Primary controller set
8950
Common flow temp
8951
Common flow temp setp
8952
Common return temp
8962
Common output setpoint
8980
Buffer temp 1
8981
Buffer setpoint
8982
Buffer temp 2
8983
Buffer temp 3
9005
Water pressure H1
9006
Water pressure H2
9009
Water pressure H3
9031
Relay output QX1
9032
Relay output QX2
9033
Relay output QX3
9034
Relay output QX4
9050
Relay output QX21 module 1
9051
Relay output QX22 module 1
9052
Relay output QX23 module 1
9053
Relay output QX21 module 2
9054
Relay output QX22 module 2
9055
Relay output QX23 module 2
132 / 136
Access
Default value
E
Off
E
Off
E
Off
S
0 %
C
20 °C
C
20 °C
E
60 °C
E
60 °C
C
No demand
C
Off
S
0 %
S
0 %
S
0 %
C
0 °C
C
55 °C
C
0 °C
C
0 °C
C
0 °C
C
0 °C
C
0 °C
C
0 l/min
C
5 °C
C
5 °C
C
5 °C
C
0 °C
C
24 °C
C
0 °C
C
0 °C
C
0 °C
C
0 °C
C
0 °C
C
0 %
C
0 °C
C
0 °C
C
0 °C
C
0 °C
C
0 bar
C
0 bar
C
0 bar
C
Off
C
Off
C
Off
C
Off
C
Off
C
Off
C
Off
C
Off
C
Off
C
Off