IDEAL Vogue S15 User Manual

Hide thumbs Also See for Vogue S15:

Advertisement

USER GUIDE
VOGUE SYSTEM
S15 S18 S26 S32
When replacing any part on this appliance, use only spare parts that you can be
assured conform to the safety and performance specification that we require.
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

Advertisement

Table of Contents
loading

Summary of Contents for IDEAL Vogue S15

  • Page 1 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.
  • Page 3: Natural Gas Only

    G.C. Appliance No. 41-750-53 Ideal Stelrad Group is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
  • Page 4 FOR ANy qUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE : 01482 498660 NOTE. BOILER RESET PROCEDURE - To reset boiler, press button “r” on the control panel. The boiler will repeat the ignition sequence if a heat demand is present...
  • Page 5: Important Notes

    IMPORTANT NOTES • This appliance must not be operated without the casing correctly fitted and forming an adequate seal. • If the boiler is installed in a compartment then the compartment mUST noT be used for storage purposes. • If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).
  • Page 6: Boiler Controls

    BOILER CONTROLS LEGEND Boiler Status Exit Button C. Down Button D. Up Button Enter Button Reset Button G. CH Temperature ON 60ºC Control H. on / off Switch Burner on indication Pressure Gauge Boiler in Full Condensing mode...
  • Page 7 TO LIGHT THE BOILER. (REFER TO BOILER If the boiler has not lit, after 5 ignition attempts, the following CONTROLS) screen will be displayed. If a programmer is fitted refer to separate instructions for the Ignition Lockout programmer before continuing. Check other Gas Appliances work Switch on electricity to the boiler and check that all If not, re-instate gas supply...
  • Page 8: Operation

    OPERATION FROST PROTECTION Central Heating If no frost protection is provided and frost is likely during a short absence from home, leave the heating controls (if fitted) at a With the external heating controls calling for heat, the on/oFF reduced temperature setting. For longer periods, the entire switch (H) set to ‘on’...
  • Page 9: Condensate Drain

    In this case the following display will appear: To unblock a frozen condensate pipe; 1. Follow the routing of the plastic pipe from its exit point on Low Water Pressure the appliance, through its route to its termination point. Fill System to 1 Bar Locate the frozen blockage.
  • Page 10: Escape Of Gas

    POINTS FOR THE BOILER USER ESCAPE OF GAS Should a gas leak or fault be suspected contact the national Note. In line with our current warranty policy we would ask that Gas Emergency Service without delay. Tel. 0800 111 999 you check through the following guide to identify any problems Do NoT SeaRCh foR GaS leakS wITh a NakeD external to the boiler prior to requesting a service engineers...
  • Page 11: Fault Finding

    FAULT FINDING If a fault occurs then a fault description and suggested potential corrective actions will be displayed. In addition the following information may be useful. Too many resets 5 boiler faults have been reset within a 15 min period. It is recommended that the boiler should be examined by a suitably qualified service engineer.
  • Page 12 BOILER CONTROLS LEGEND Boiler Status Exit Button C. Down Button D. Up Button Enter Button Reset Button G. CH Temperature ON 60ºC Control H. on / off Switch Burner on indication Pressure Gauge Boiler in Full Condensing mode...
  • Page 13 DISPLAy MESSAGES DISPLAy MESSAGES (WITH OUTSIDE SENSOR) (WITHOUT OUTSIDE SENSOR) Indicates that the Boiler is Switched off move the on/off Switch into the on Indicates that the Boiler is Switched off position to switch the Boiler on move the on/off Switch into the on position to switch the Boiler on Indicates that either the Hot Water Timer is off or the Cylinder Stat is off...
  • Page 14 DISPLAy MESSAGES (GENERAL) CHANGE SETTINGS (BASIC) To change the Maximum Boiler Indicates that the temperature at the boiler is less Temperature rotate the Boiler than 5°C and that the boiler is running to protect itself °C Temperature Control from frost damage This screen will be shown 4°C Set Boiler Temperature...
  • Page 15: Change Settings

    5 CHANGE SETTINGS Efficiency Level System Frost Protection To view the efficiency level of the boiler press ENTER and the This feature can only be accessed if an outside sensor has following screen will be displayed. been connected. The pump will run continuously if the outside temperature is less than 5ºC.
  • Page 16 CHANGE SETTINGS Reset Service Time Set Zone 2 Flow Temperature If the boiler has not been serviced within the last 12 months then If an outside sensor is connected to the boiler then the a message will be displayed indicating this. To reset this timing flow temperature target for Hot Water operation can be set proceed as follows.
  • Page 20 2014 UIn 208551 A03 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482...