Amp Control Board: ........ This board is located in the main contactor box
Beater Run: ..................... This D.O.B. timer used to delay the beater motor after
Demand Run Comp: ....... The D.O.B. timer used to delay the compressor when
Dual Diff: ......................... The differential used when product is being drawn out of
Differential (Hyst): ........... Symbolizes the differential setting. Hysteresis range: 7 to
Idle Run Comp: ............... Delay on break (D.O.B.) timer used for the compressor
Idle: ................................. When the unit is cycling on temperature and no product
Lock outs: ........................ Allows the function of a specific feature/button to be
Main P.C. Board: ............. Main Control board for the unit, housed behind the trim
Membrane Switch: .......... The black Electro Freeze decal visible on the front of the
Single Diff: ...................... The differential used when product is being drawn out of
Slope/Demand Slope: .... Utilizes a function within the system to watch the
8
responsible for monitoring the beater motor amperage
and communicating that value to the main P.C. Board.
the refrigeration shuts down. Beater Run Range: 0 to 10
seconds
product is being drawn. Demand Run Comp. Range: 0 to
12 seconds
the center spigot or when both side spigots have been
drawn simultaneously. Dual Hysteresis range: 7 to 20°F
20°F i.e. if your cut in is at 18°F and your Hysteresis is
at 10°F your unit will cut out at 8°F
when the unit is in idle mode/no product being drawn.
Idle Run Comp. Range: 0 to 20 seconds
is being dispensed
temporarily disabled to deter unnecessary usage of that
feature.
strip panel. This board has many connectors on it and is
responsible for the main operations of the unit.
unit, which houses the hidden operator, technician, soft,
and hard keys used to navigate the menus
one barrel. Single Hysteresis range: 7 to 20°F
temperature change as the unit freezes a barrel. If
utilizing the slope feature and the unit sees a lack of
temperature change during freeze down, the unit will
cycle off. This will prevent a freeze up condition due to a
long run time. Demand Slope range: 0 to -0.2