ELECTRO FREEZE SLX400E Operator's Manual page 41

Genesis series
Table of Contents

Advertisement

10.2.2 Priming Instructions for Freezers Built into a Wall
1. Place a bucket under the dispense
head. Remove the actuator rod from
the spigot. Leave spigot open. (figure
10-4)
2. Fill mix hopper with one gallon of mix
and allow mix to push out remaining
sanitizer. When pure mix is flowing
from the dispense head close the
dispense handle (figure 10-4).
Reinstall the actuator rod.
Failure to completely remove sanitizer
or water from the freezing cylinder
before placing in
damage the freezer.
3. Press the
the freezer.
4. Repeat Steps 1 - 3 for the other side
of the freezer.
5. Sanitize and install nozzles.
"OPEN" - READY TO SERVE
Figure 10-5 "OPEN" — position
184584
ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
Important:
freeze will
freeze button to start
"CLOSED"-FILL WITH MIX
Figure 10-6 "CLOSED" — position
31