ELECTRO FREEZE SLX400E Operator's Manual page 52

Genesis series
Table of Contents

Advertisement

ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
14
Trouble Shooting Tables
PROBLEM
PROBABLY CAUSE
1.
Compressor
will not
start – hums
2.
intermittently
(cycling on
overload)
3.
4.
1.
Poor or slow
product
2.
recovery.
3.
1.
2.
Beater motor
does not
3.
operate.
4.
5.
6.
42
Low line voltage.
Improperly wired.
Open start capacitor or current relay.
High discharge pressure.
Dirty or blocked condenser, restricted air
flow – high ambient temperature.
Defective condenser fan motor.
Component or compressor failure.
Head assembly is not installed.
Magnetic head switch defective.
Loose connection in control circuit.
Open starter coil.
Faulty capacitor assembly. (Single
phase only.)
Faulty beater motor.
(continued)
REMEDY
Ask power company to increase
voltage to not less than 10% below
1.
dataplate rating or have transformer
installed. Have electrician check for
adequate wire size.
Contact your Electro Freeze
2.
distributor for service.
Contact your Electro Freeze
3.
distributor for service.
Contact your Electro Freeze
4.
distributor for service.
Have condenser cleaned by your
1.
Electro Freeze distributor; lower
ambient temperature.
Contact your Electro Freeze
2.
distributor for service.
Contact your Electro Freeze
3.
distributor for service.
1.
Install head assembly.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
3.
Distributor for service.
Contact your Electro Freeze
4.
Distributor for service.
Contact your Electro Freeze
5.
Distributor for service.
Contact your Electro Freeze
6.
Distributor for service.