ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
14
Trouble Shooting Tables
PROBLEM
PROBABLY CAUSE
1.
2.
Unit does not
operate.
3.
4.
5.
Leakage of mix
1.
or water from
drain tube to
2.
drip tray.
3.
Compressor
1.
does not
operate or
operates
improperly.
2.
1.
Dispensed
product too
2.
soft.
3.
40
Freezer unplugged.
Fuse or breaker blown at main
disconnect.
Off on high pressure cut-out control.
Off on low pressure cut-out control.
Disconnected or broken wire in electrical
circuit.
Damaged beater shaft seal or installed
improperly.
Beater shaft pitted or damaged where
o-ring rides.
Beater shaft end play not set properly.
Faulty contactor.
Disconnected or broken wire in switch.
Dirty or blocked condenser, restricted air
flow.
Component failure.
Leak in refrigeration system resulting in
little or no refrigeration.
(continued)
REMEDY
1.
Plug in freezer.
Make sure your freezer is connected
to a separate circuit independent
from any other electrical equipment.
2.
Have technician check fuse or
breaker size and check voltage; if not
within 10% of nameplate rating call
power company.
Refer to Troubleshooting Table –
3.
Discharge pressure too high.
Contact your Electro Freeze
4.
distributor for service.
Contact your Electro Freeze
5.
distributor for service.
Replace cup seals on washer. Install
1.
properly.
2.
Replace beater shaft.
Contact your Electro Freeze
3.
distributor for service.
Contact your Electro Freeze
1.
Distributor for service.
Contact your Electro Freeze
2.
Distributor for service.
Unblock condenser or have cleaned
1.
by your Electro Freeze Distributor.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
3.
Distributor for service.
184584