ELECTRO FREEZE SLX400E Operator's Manual page 53

Genesis series
Table of Contents

Advertisement

14
Trouble Shooting Tables
PROBLEM
PROBABLY CAUSE
1.
2.
Unit operates
long or
continuously.
3.
4.
1.
2.
3.
Discharge
pressure too
4.
high.
5.
6.
7.
1.
Discharge
pressure too
low.
2.
1.
Noisy
compressor.
2.
184584
ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
Dirty condenser.
Shortage of refrigerant.
Moisture in system.
Compressor failing.
Water hose kinked or pinched. (water
cooled models)
Water turned off or defective water
regulating valve. (water cooled models)
Restricted water cooled condenser.
(water cooled models)
Dirty air condenser. (air cooled models)
Unit location too warm (air cooled
models)
Refrigerant overcharge.
Air in system.
Water regulating valve open too wide.
(water cooled model)
Shortage of refrigerant.
Tubing rattles.
Spring broken internally.
(continued)
REMEDY
Have condenser cleaned by your
1.
Electro Freeze distributor.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
3.
Distributor for service.
Contact your Electro Freeze
4.
Distributor for service.
Move freezer and adjust hose so it is
1.
not pinched or kinked.
Turn on water, or contact your Electro
2.
Freeze Distributor for service.
Contact your Electro Freeze
3.
Distributor for service.
Contact your Electro Freeze
4.
Distributor for service.
Contact your Electro Freeze
5.
Distributor for service.
Contact your Electro Freeze
6.
Distributor for service.
Contact your Electro Freeze
7.
Distributor for service.
Contact your Electro Freeze
1.
Distributor for service.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
1.
Distributor for service.
Contact your Electro Freeze
2.
Distributor for service.
43