10.1
Sanitizing
6. Reconnect main power supply. Place
the power switch in the "ON" position.
Do not use the
with water or sanitizer in the cylinder.
The freezer will be damaged.
7. When the cylinders have filled with
sanitizing solution, press the soft key
under the
ON" for both sides of the freezer and
allow the beaters to run for 5 minutes.
During this time period, check for
leaks around the head, plungers and
drain tubes.
8. Press "BEATER OFF" on both
sides. Place an empty container
under the dispensing head and drain
the sanitizing solution by opening
the plungers to allow cylinders and
hoppers to empty. Open and close
each plunger at least 10 times during
draining to sanitize the port area of
dispense head.
9. When the sanitizing solution has
drained from the freezer, press the
184584
ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
(continued)
Important:
freeze position
icon and "BEATER
"OFF" button.
29