FUEL SYSTEM
STARTING ENRICHMENT (SE) VALVE
Coat a new O-ring with oil and install it to the SE
valve.
Install the SE valve into the carburetor until it fully
seated.
Install the setting plate onto the SE valve groove.
Install the SE valve into the carburetor body as
shown.
Install and tighten the screw securely.
TORQUE: 2.1 N m (0.21 kgf m, 1.5 Ibf-ft)
Install the throttle position sensor (page 16-9).
Connect the water hose to the carburetor.
CARBURETOR INSTALLATION
After '05 model: Install the intake manifold plate and gasket.
WATER HOSE
INTAKE MANIFOLD
VALVE
SETTING PLATE
THROTTLE
POSITION SENSOR
INTAKE MANIFOLD PLATE
5-16