Install the thermostat housing
tighten the bolts securely.
cover, stay and
STAY
COVER
BOLTS
WATER PUMP
Clean the inside of the outer magnet and the water
pump magnet, and check that no nuts or bolts are
magnetically attached to the magnet.
Coat a new O-ring with engine oil and install it into
the groove into the water pump.
WATER PUMP MAGNET
Install the water pump into the cylinder head and
tighten the bolts securely.
Connect the water hoses and install the clamp
securely.
Install the wire band onto the stay.
WATER HOSES