Battery/Charging System Specifications; Ignition System Specifications; Lights/Meters/Switches Specifications - Honda Metropolitan CHF50 Service Manual

Hide thumbs Also See for Metropolitan CHF50:
Table of Contents

Advertisement

GENERAL INFORMATION
BATTERY/CHARGING SYSTEM SPECIFICATIONS
ITEM
Battery
Alternator
Capacity
Current leakage
Voltage (20 °C/68 °F)
Charging current
Fully charged
Needs charging
Normal
Quick
Capacity
Charging coil resistance (20 °C/68 °F)
SPECIFICATIONS
12V-6 Ah
0.1 mA max.
13.0-13.2V
Below 12.3V
0.6A/5-10h
3A/1h
190W/5,000rpm
0.05- 0.5 Q
IGNITION SYSTEM SPECIFICATIONS
ITEM
Spark
plug
Standard
For cold climate (below 5 °C/41 °F)
For extended high speed riding
Spark plug gap
Ignition coil peak voltage
Ignition pulse generator peak voltage
Ignition timing ("F" mark)
Throttle position
sensor
Resistance (20 °C/68 °F)
Input voltage
SPECIFICATIONS
CR8EH-9 (NGK), U24FER9 (DENSO)
CR7EH-9 (NGK), U22FER9 (DENSO)
CR9EH-9 (NGK), U27FER9 (DENSO)
0.80 - 0.90 mm (0.031 - 0.035 in)
80 V minimum
0.7 V minimum
10°BTDC at 2,000 rpm
4 - 6 k O
4.7 - 5.3 V
LIGHTS/METERS/SWITCHES SPECIFICATIONS
ITEM
Bulbs
Fuse
Headlight (high/low beam)
Brake/tail light
Front turn signal light
Rear turn signal light
License light
Instrument light
Turn signal indicator
High beam indicator
Water temp indicator
Main fuse
Sub fuse
ECT sensor resistance
Fuel pump
At50°C/122°F
At 130°C/266°F
Resistance (20 °C/68 °F)
Flow capacity
SPECIFICATIONS
12V-35/35W
12V-23/8W
12V-21WX2
12V-21WX2
12V-5W
12V-1.7WX2
12V-3.4W
LED
LED
15A
10AX2
690 - 860 Q.
68 - 83 Q
2.6- 3.2 Q.
100 cm
3
(3.4 US oz, 3.5 Imp oz) minimum/minute
1-9