SYSTEM MENU
Here is where you set GPI functions for main GPI or Livewire GPI.

GPI Function A-D / E-H

The Function control in each GPI channel - A through H - determines which available parameter is affected when the
input signal is received.
The Lo and Hi controls work together to determine the specific action that occurs to the parameter selected by the
Function control.
Livewire GPI functions are set by selecting a LW GPI tab and selecting the desired function responses.
Pins 2 through 9 are GPI inputs 1 through 8. Pins 18 through 25 are ground.
If a system is using relay logic, a contact closure from GPI to ground is "engaged" and an open contact is "not engaged".
If supplied by a 5V GPO, 0V is GPI "engaged" and 5V is GPI "not engaged". A 3.3V signal will also work.
For continuous behavior, use one GPI for the action as follows:
LO - Setting 1
HI - Setting 2
For momentary behavior, use two GPI's for the action as follows:
GPI 1 LO - Setting 1
GPI 1 HI - No change
GPI 2 LO - Setting 2
GPI 2 HI - No change
Always remember to re-enable GPI after making any changes!