LED Status
System Ready
Electric Field
Magnetic Field
System Ready
Electric Field
Magnetic Field
5.2 No Audible Messages
In the event that no audible messages are heard during operation of the D-TEC, check the
wiring of the remote speaker.
5.3 Unable to Override D-TEC
In the event that overriding the D-TEC cannot be accomplished, check:
The state of the Keylock Switch
The state of the Override Switch
The wiring for the Override and Keylock Switches
TP-5522901-00
July 2018
Table 5-1 State Indications Continued
Text
Audible
Message
Message
(Buzzer) "Electric
Power LN
Field"
XX.XKV/M
(Buzzer) "OSHA
OSHA Limit
Limit"
D-TEC
O
PERATOR
Root Issue
The unit has detected
a large AC voltage
field, suggesting the
nearness of a power
line. The approximate
magnitude of this field
kV/m
is shown in
(kilovolts per meter).
The unit has detected
a very large AC
voltage field,
suggesting the
nearness of a high
voltage power line.
'
M
S
ANUAL
Troubleshooting /
Potential Causes
Move mast away
from power line or
voltage source.
Move mast away
from power line or
voltage source.
5-5