2.6.2.7 Electrically Connect the Sensor
The operator should use the provided 150 ft. (45.7 meter) 4-conductor cable (P/N: 000018-500-
001) when electrically connecting the Sensor. This cable is typically run through a Nycoil.
To electrically connect the Sensor (Figure 2-19):
1. As necessary, run the cable through a Nycoil.
2. Secure the:
a. Red 18 AWG wire to the DB9 Terminal Block where the brown wire from DB9
connects.
b. Black 18 AWG wire to the DB9 Terminal Block where the blue wire from DB9
connects.
c. White 22 AWG wire to the DB9 Terminal Block where the white wire from DB9
connects.
d. Green 22 AWG wire to the DB9 Terminal Block where the green wire from DB9
connects.
e. Shield / drain wire to the DB9 Terminal Block where the shield wire from DB9
connects.
3. Secure the 4-Pin MS3106E14S-2S Plug (P/N: 000013-202-005) from the Installation Kit
to the end of the cable as follows:
a. Red 18 AWG wire to B.
b. Black 18 AWG wire to C.
c. White 22 AWG wire to A.
d. Green 22 AWG wire to D.
4. Secure the 4-Pin Plug to the Sensor.