2.6.2.10 Install Remote Annunciators (Optional)

Through J5 on the Display, the D-TEC has outputs suitable for driving optional remote
annunciators such as small incandescent pilot lights, LEDs, or small audible or visual alarms.
Note: These outputs cannot supply large amounts of current. A maximum output of 750 mA for
all outputs can be supplied. A maximum output of 250 mA for any one output can be supplied.
Wire any remote annunciators according to Figure 2-24.

2.6.2.11 Install Remote Computer (Not Supplied)

The D-TEC has certain functionality that is available through a standard RS-232 connector
(Figure 2-25). This is primarily used by factory authorized service centers and in Stiletto
applications involving PC operation in order to allow the mission computer to know the
fault/status conditions of the Display.
TP-5522901-00
July 2018

Figure 2-24 J5 Wiring

Figure 2-25 J4 Wiring

'