Table 5-1 State Indications - Will Burt D-Tect 5354901 Operator's Manual

Sensor shown, rack mount display shown, wall mount display shown
Table of Contents

Advertisement

'
D-TEC O
M
PERATOR
S
LED Status
System Ready
Electric Field
Magnetic Field
System Ready
Electric Field
Magnetic Field
System Ready
Electric Field
Magnetic Field
System Ready
Electric Field
Magnetic Field
System Ready
Electric Field
Magnetic Field
System Ready
Electric Field
Magnetic Field
System Ready
Electric Field
Magnetic Field
5-2
ANUAL

Table 5-1 State Indications

Text
Audible
Message
Message
"Running
SelfTst
Diagnostics"
(Buzzer) "Sensor
VR Fault
Fault"
(Buzzer) "Sensor
LP Fault
Fault"
(Buzzer) "Sensor
EF Fault
Fault"
(Buzzer) "Sensor
EP Fault
Fault"
(Buzzer) "Sensor
HF Fault
Fault"
(Buzzer) "Sensor
HW Fault
Fault"
Root Issue
The unit is running a
self-test. This is
performed each time
the unit powers up or
has been reset. Once
the self-test is
complete and no
faults are found, the
System Ready green
LED will illuminate.
The unit has detected
a fault in the power
supply circuit or the
internal reference
circuits during the
self-test procedure.
The unit has detected
a fault in the Look-Up
Light (lamp) circuit
during the self-test
procedure.
The unit has detected
a fault in the AC
voltage detection
electric field
(
) circuit
during the self-test
procedure.
The unit has a
temperature sensor
SPI communication or
EEprom fault detected
during self-test.
The unit has detected
a fault in the AC
current Detection
(magnetic field) circuit
during the self-test
procedure.
The unit has detected
a fault in the hardware
circuitry during the
self-test procedure.
Troubleshooting /
Potential Causes
N/A
Possible
inadequate wiring
(see Section
2.6.2.12).
Check wiring or
notify The Will-Burt
Company.
Notify The Will-Burt
Company if
problem persist.
Possible Proximity
to AC voltage field
during self-test.
Notify The Will-Burt
Company if
problem persists.
Notify The Will-Burt
Company if
problem persists.
Possible Proximity
to AC current field
during self-test.
Notify The Will-Burt
Company if
problem persists.
Notify The Will-Burt
Company if
problem persists.