Install Up/Down Switch; Figure 2-13 Install The Up/Down Switch - Will Burt D-Tect 5354901 Operator's Manual

Sensor shown, rack mount display shown, wall mount display shown
Table of Contents

Advertisement

'
D-TEC O
M
PERATOR
S

2.6.2.2 Install Up/Down Switch

The Up/Down Switch (P/N: 908510) is a Single Pole Double Throw (SPDT) On-Off-Momentary
On switch, used to extend and retract the mast. The Up/Down Switch shall be wired so that the
Up function is momentary. The operator should use a customer-supplied 3-conductor 20 AWG
cable for installation.
To install the Up/Down Switch (Figure 2-13):
1. Install the Up/Down Switch keeping in mind that:
The Override/Clear Switch will need to be installed near the Up/Down Switch so
that the same operator may use both switches.
The Keylock Switch will need to be installed at least six feet (183 cm) or greater
from the Override/Clear Switch so that it is impossible for one person to operate
both simultaneously. The distance should force a two-person override.
All switches need to allow the top of the mast to always be visible to the operator
while engaged.
2. Secure the:
a. Mast up input cable from the Up/Down Switch to the DB25 Terminal Block where
the orange wire from DB25-14 connects.
b. Mast down input cable from the Up/Down Switch to the DB25 Terminal Block
where the yellow wire from DB25-15 connects.
c. Common cable from the Up/Down Switch to the DB25 Terminal Block where the
shielded wire from DB25-1 connects.
2-18
ANUAL

Figure 2-13 Install the Up/Down Switch

TP-5522901-00
July 2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-tect 5354701D-tect 5354801

Table of Contents