Start Up - ERGO-FIT Power Line 4000 Owner's Manual

Hide thumbs Also See for Power Line 4000:
Table of Contents

Advertisement

6

Start up

Connect the machine to a dedicated power supply (110...220VAC) and avoid using an
extension cord or a multi-outlet power strip. If necessary, please EN 60601-1 extension
cords or power strips. After switching on the machine have to wait 35 minutes before
you can use the machine. During this warm-up period you can adjust the weight
plates. After the warm-up period the weight plates should be correctly displayed in the
Cockpit. You can now start your workout. We recommend DC-isolated cables for the
connection of external equipment to a POWER LINE 4000 MED machine
6.1
Calibrating the Weight Plates
Before any new calibration/re-calibration of the weight plates you have to consider a
warm-up period of 35 minutes. The warm-up period starts as soon as you switch on
the machine. Re-calibration is only possible after the warm-up period has finished.
Otherwise the weight plates may be displayed incorrectly in the Cockpit or may adjust
automatically.
Note: The workout machine with laser sensor is a precision measuring instrument. But
even here you have to consider measuring tolerances due to environmental factors
(temperature changes, operation time etc.). Therefore, we recommend to check the
functionality of the machine regularly. In case of a the weight plate difference you have
to perform a re-calibration.
6.2
Resistance adjustment
On all machines of the POWER LINE4000 series the resistance can be adjusted by
adding or reducing the number of snap-on weights. Dowel pins are used to adjust the
weight by inserting them into the borings in the snap-on weights. The weights may be
chosen directly from the machine.
When adjusting, consider the following aspects:
You can only adjust the weights when the weight bundle is not under tensile
stress and the snap-on weights are resting firmly. Accordingly, you should avoid
modifying the training weight during a motion sequence.
Make sure to insert the dowel pins completely. If this is not the case, the pins
might loosen during motion. The snap-on weights can fall on the weight bundle
and this might damage the weights or injure the trainee because of jerky removal
of the load.
To secure the weights, insert the dowel pins straight into the borings. Otherwise,
the dowel pins might tilt during motion.
Do not put your hands between the snap-on weights. Otherwise, there is a risk
4 2