System Management Commands

logging timestamp

To set the logging time-stamp units, use the logging timestamp command. To reset the logging
time-stamp units to the default, use the no form of this command.
Syntax Description
microseconds
milliseconds
seconds
Command Default
None
Command Modes
Global configuration mode
Command History
Release
5.0(3)A1(1)
Usage Guidelines
By default, the units are seconds.
Examples
This example shows how to set the logging time-stamp units to microseconds:
switch# configure terminal
switch(config)# logging timestamp microseconds
switch(config)#
Related Commands
Command
show logging
timestamp
OL-27851-02
logging timestamp {microseconds | milliseconds | seconds}
no logging timestamp {microseconds | milliseconds | seconds}
Specifies the units to use for logging timestamps in microseconds. The
default units are seconds.
Specifies the units to use for logging timestamps in milliseconds.
Specifies the units to use for logging timestamps in seconds. The default
units are seconds.
Modification
This command was introduced.
Description
Displays the logging time-stamp configuration.