Omron NT31 Operation Manuals page 627

Programmable terminal
Hide thumbs Also See for NT31:
Table of Contents

Advertisement

Examples of Actual Applications of Memory Link
To know the event that a numeral/character string is input to PT
Example:
616
Screen switch is executed by writing the screen number to the first word in PT con-
trol area.
In this example, screen is switched from screen No.10 to screen No.15.
"000F" is specified in the example above since it is necessary to specify data of
written word in PT memory write command in binary.
If "Yes" is set for the "Response" memory switch for the communication setting of
memory link, the response indicated below is returned from PT after sending com-
mand. (If "No" is set, no responses will be returned.)
S Response
[ESC]
W
M
1B
57
4D
38
S Explanation
Format of response is fixed.
Hint
S In the same way, by changing the status of PT control bit, buzzer can be beeped
or backlight ON/OFF status can be controlled from the host. see page ??
S By writing the value in window control area, it is possible to control window
(open/close/move). see page ??)
S Use "bit memory table write command" to switch screens by the operation of bit
memory table. see page ??
NT31/NT31C
Production
volume
0001
No. of
0005
parts
Numeral input and numeral display
(Input production volume number
of required parts is calculated at
the host
The returned result is displayed)
When the numeral was input on PT, "numeral input notify command" (sent from PT
to host) is issued from the PT. At the host, numeral data was taken out and pro-
cessed, then it is written to the PT by the "numeral memory table write command"
(sent from host to PT).
0
0
1
F
30
31
46
Numeral data
Processed data
Section 10-2
[CR]
0D
Host