Omron NT31 Operation Manuals page 299

Programmable terminal
Hide thumbs Also See for NT31:
Table of Contents

Advertisement

Memory Tables
288
- Stored data
The table below indicates how the set "Value" (initial value) and the contents of
host words are stored in numeral memory tables.
Storage of "Value" set at the Support Tool
Input Value
Storage Type
BCD
123456
Binary
BCD
−123456
Binary
BCD
$F001
Binary
BCD
$FFFF
Binary
BCD
$FFFFFFFF
Binary
Storage of contents of host words
Contents of
Storage Type
Word
BCD
1234
Binary
BCD
F123
Binary
BCD
123B
Binary
BCD
F0001234
Binary
BCD
FFFF
Binary
BCD
0000FFFF
Binary
BCD
FFFFFFFF
Binary
Number
Display After
of Words
Confirmation
123456
2
123456
−123456
2
−123456
61441
1
61441
65535
1
65535
−1
2
−1
Number
Stored Value
of Words
000004D2
1
00001234
FFFFFF85
1
FFFFF123
(not stored ... existing value retained)
1
0000123B
FFFFFB2E
2
F0001234
(not stored ... existing value retained)
1
FFFFFFFF
(not stored ... existing value retained)
2
0000FFFF
(not stored ... existing value retained)
2
FFFFFFFF
Section 7-3
Stored Value
0001E240
0001E240
FFFE1DC0
FFFE1DC0
0000F001
0000F001
0000FFFF
0000FFFF
FFFFFFFF
FFFFFFFF
Decimal for
Stored Value
1234
4660
−123
−3805
4667
−1234
−268430796
−1
65535
−1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt31c

Table of Contents