Commands/Responses
Response
[Format]
[Function]
Reference: S Data written by a numeral memory table write command is written according to
580
Only if "Yes" is set for the "Response" memory switch, the response indicated be-
low is returned on normal completion.
W
N
[
]
ESC
1B
57
4E
s
, s
:
Check sum (2 hexadecimal digits)
1
2
This is always added (fixed as "20H").
S Writes the data of the specified number of numeral memory tables, starting from
the specified numeral memory tables.
S A maximum of 20 tables can be written at one time.
S When writing is executed to numeral memory tables from No.247 to No.253
(areas for clock data display/reading use only), operation will be finished normal-
ly without writing values.
the numeral storage type of the numeral. Numeral storage type can be set at the
Support Tool. (It is possible to set it by a system memory at a PT collectively.)
e.g.) Writing 1234 to the numeral memory table No.0 (allocated word: 1)
Written data
1234
S For details of function and setting of numeral storage type, refer to "NT-series
Support Tool for Windows 95/98 (Ver.3.0) Operation Manual" (V053--E1).
0
0
s1
s2
30
30
32
30
Numeral Strage Type
BCD
Binary
Section 9-3
]
[CR
0D
Numeral Memory Table No. 0
04D2
1234