GE Multilin 565 Instruction Manual page 53

Feeder management relay
Table of Contents

Advertisement

Location
Message Line
Amp Demand Alarm Relay
KW Demand
KW Demand Time Period
KW Demand Alarm
KW Demand Alarm Level
KW Demand Alarm Relay
KVAR Demand
KVAR Demand Time Period
KVAR Demand Alarm
KVAR Demand Al'm Level
KVAR Demand Al'm Relay
11. MTM Metering setpoints.
MTM Comm. Alarm
MTM Comm. Alarm Relay
MTM CT Select
MTM CT Rating Primary
Power Factor Alarm
P/F Leading Alarm Level
P/F Lagging Alarm Level
P/F Alarm Delay
P/F Alarm Relay
Power Factor Trip
P/F Leading Trip Level
P/F Lagging Trip Level
P/F Trip Delay
P/F Trip Relay
Frequency Alarm
Under Freq. Alarm Level
Over Freq. Alarm Level
Frequency Alarm Delay
Frequency Alarm Relay
Frequency Trip
Under Freq. Trip Level
Over Freq. Trip Level
Frequency Trip Delay
Frequency Trip Relay
MTM Scaling Factor
Voltage Reversal Trip
Voltage Reversal Delay
Voltage Reversal Relay
12. Auto Reclosure setpoints. (575 only)
Auto Reclosure
No. Of Reclose Shots
Shot 1 Dead Time
Shot 2 Dead Time
Shot 3 Dead Time
Shot 4 Dead Time
Scheme Reset TIme
Reclosure Enable Relay
13. Phase Curves setpoints. (575 only)
Description
Aux1. (Aux2 for 575)
Enabled.
5 Min.
Disabled.
1000 kW.
Aux1. (Aux2 for 575)
Enabled.
5 Min.
Disabled.
1000 kVAR.
Aux1. (Aux2 for 575)
Disabled.
Aux2.
Common.
100 A.
Disabled.
0.75.
0.75.
5.0 Sec.
Aux1. (Aux2 for 575)
Disabled.
0.70.
0.70.
1.0 Sec.
Aux1. (Trip&Aux1 for 575)
Disabled.
58.0 Hz.
62.0 Hz.
5.0 Sec.
Aux1. (Aux2 for 575)
Disabled.
56.0 Hz.
64.0 Hz.
1.0 Sec.
Aux1. (Trip&Aux1 for 575)
655.
Disabled.
1.0 sec.
Trip
Disabled.
4.
2.0 sec.
4.0 sec.
6.0 sec.
8.0 sec.
5.0 sec.
Aux2.
Aux1, Aux2, Aux1&2 (575: None, Aux1, Aux2, Aux1&2)
Enabled/Disabled
5 to 120 Min
Enabled/Disabled
100 to 65,000 kW
Aux1, Aux2, Aux1&2 (575: None, Aux1, Aux2, Aux1&2)
Enabled/Disabled
5 to 120 Min
Enabled/Disabled
100 to 65,000 kVAR
Aux1, Aux2, Aux1&2 (575: None, Aux1, Aux2, Aux1&2)
Enabled/Disabled
Aux1, Aux2, Aux1&2
Common/Separate
5 to 5000 A
Enabled/Disabled
0 to 1
0 to 1
1 to 127 sec
Aux1, Aux2, and Aux1&2 (575: None, Aux1, Aux2,
Aux1&2)
Enabled/Disabled
0 to 1
0 to 1
1 to 127 sec
Trip, Aux1, Aux2, Trip&Aux1, Trip&Aux2, Aux1&2, and
Trip&Aux1&2 (575: Trip, Trip&Aux1, Aux2)
Enabled/Disabled
40 to 60 Hz
50 to 72 Hz
1 to 127 sec
Aux1, Aux2, Aux1&2 (575: None, Aux1, Aux2, Aux1&2)
Enabled/Disabled
40 to 60 Hz
50 to 72 Hz
1 to 127 sec
Trip, Aux1, Aux2, Trip&Aux1, Trip&Aux2, Aux1&2, and
Trip&Aux1&2 (575: Trip, Trip&Aux1, Aux2)
1 to 655
Enabled/Disabled
1 to 127 sec.
Trip, Aux1, Aux2, Trip&Aux1, Trip&Aux2, Aux1&Aux2,
Trip&Aux1&Aux2 (575: Trip, Trip&Aux1, Aux2)
Enabled/Disabled
0 to 4
0.3 to 300 sec.
0.3 to 300 sec.
0.3 to 300 sec.
0.3 to 300 sec.
1 to 255 sec.
None, Aux1, Aux2, Aux1&2
SETPOINTS MODE
1 Min
100 kW
1 Min
100 kVAR
5 A
0.05
0.05
0.5 sec
0.05
0.05
0.5 sec
0.1 Hz
0.1 Hz
0.5 sec
0.1 Hz
0.1 Hz
0.5 sec
1
0.5 sec
1
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
1 sec.
5-9