Test and valve setting of OSPE

Check for external leakage

OSPE Steering Valve
Adjust the pressure (R-T/L-T) by adjusting screws of shock valves (item 64) to the specified value for the
shock valve setting for the code in question.
After testing of the former items, the steering column (wheel) and port connections are removed. P, L, R,
EF and LS ports are to be plugged and oil pressure of 20 bar is supplied to the T port for approx. 3
minutes: No leakage must be found in any assemblies or at the input shaft for the steering column.