Interface And Hardware Component Configuration Guide For Cisco Ncs 5500 Series Routers, Ios Xr Release - Cisco NCS 5500 Series Configuration Manual

Interface and hardware component configuration
Hide thumbs Also See for NCS 5500 Series:
Table of Contents

Advertisement

Configuring Ethernet CFM
SUMMARY STEPS
1. configure
2. ethernet cfm
3. domain domain-name level level-value [id [null] [dns DNS-name] [mac H.H.H] [string string] ]
4. service service-name {bridge group bridge-domain-group bridge-domain bridge-domain-name |
down-meps | xconnect group xconnect-group-name p2p xconnect-name}[id [icc-based icc-string
umc-string] | [string text] | [number number] | [vlan-id id-number] | [vpn-id oui-vpnid]]
5. maximum-meps number
6. log {ais|continuity-check errors|continuity-check mep changes|crosscheck errors|efd}
7. end or commit
DETAILED STEPS
Command or Action
Step 1
configure
Example:
RP/0/RP0/CPU0:router# configure
Step 2
ethernet cfm
Example:
RP/0/RP0/CPU0:router# ethernet cfm
Step 3
domain domain-name level level-value [id [null]
[dns DNS-name] [mac H.H.H] [string string] ]
Example:
RP/0/RP0/CPU0:router(config-cfm)# domain
Domain_One level 1 id string D1
Step 4
service service-name {bridge group
bridge-domain-group bridge-domain
bridge-domain-name | down-meps | xconnect
group xconnect-group-name
p2p xconnect-name}[id [icc-based icc-string
umc-string] | [string text] | [number number] |
[vlan-id id-number] | [vpn-id oui-vpnid]]
Example:
RP/0/RP0/CPU0:router(config-cfm-dmn)#
service Bridge_Service bridge group BD1
bridge-domain B1

Interface and Hardware Component Configuration Guide for Cisco NCS 5500 Series Routers, IOS XR Release

6.1.x
56
Purpose
Enters global configuration mode.
Enters the Ethernet Connectivity Fault Management (CFM)
configuration mode.
Creates and names a container for all domain configurations and
enters the CFM domain configuration mode.
The level must be specified.
The id is the maintenance domain identifier (MDID) and is used as
the first part of the maintenance association identifier (MAID) in
CFM frames. If the MDID is not specified, the domain name is used
as the MDID by default.
Configures and associates a service with the domain and enters CFM
domain service configuration mode. You can specify that the service
is used only for down MEPs, or associate the service with a bridge
domain or xconnect where MIPs and up MEPs will be created.
The id sets the short MA name.
Configuring Ethernet OAM