Ethernet Cfm Show Command: Examples - Cisco NCS 5500 Series Configuration Manual

Interface and hardware component configuration
Hide thumbs Also See for NCS 5500 Series:
Table of Contents

Advertisement

Configuration Examples for Ethernet CFM
mep domain Dm1 service Sv1 mep-id 1
commit

Ethernet CFM Show Command: Examples

These examples show how to verify the configuration of Ethernet Connectivity Fault Management (CFM):
Example 1
This example shows how to display all the maintenance points that have been created on an interface:
RP/0/RP0/CPU0:router# show ethernet cfm local maintenance-points
Domain/Level
-------------------- ------------------- ----------------- ------ ---- --------
fig/5
fig/5
fred/3
Example 2
This example shows how to display all the CFM configuration errors on all domains:
RP/0/RP0/CPU0:router#
Domain fig (level 5), Service bay
* MIP creation configured using bridge-domain blort, but bridge-domain blort does not exist.
* An Up MEP is configured for this domain on interface TenGigE0/0/0/3 and an Up MEP is
also configured for domain blort, which is at the same level (5).
* A MEP is configured on interface TenGigE0/0/0/1 for this domain/service, which has CC
interval 100ms, but the lowest interval supported on that interface is 1s
Example 3
This example shows how to display operational state for local maintenance end points (MEPs):
RP/0/RP0/CPU0:router# show ethernet cfm local meps
A - AIS received
R - Remote Defect received
L - Loop (our MAC received)
C - Config (our ID received)
X - Cross-connect (wrong MAID)
P - Peer port down
Domain foo (level 6), Service bar
ID Interface (State)
----- ------------------------ --- -------- -- ------- ---
100 Gi1/1/0/1 (Up)
Domain fred (level 5), Service barney
ID Interface (State)
----- ------------------------ --- -------- -- ------- ---
2 Gi0/1/0/0 (Up)
Domain foo (level 6), Service bar
ID Interface (State)
----- ------------------------ --- -------- -- ------- ---
100 Gi1/1/0/1 (Up)
Domain fred (level 5), Service barney
ID Interface (State)
----- ------------------------ --- -------- -- ------- ---
2 Gi0/1/0/0 (Up)
Interface and Hardware Component Configuration Guide for Cisco NCS 5500 Series Routers, IOS XR Release
6.1.x
70
Service
Interface
bay
Gi0/10/0/12
bay
Gi0/0/1/0
barney
Gi0/1/0/0
show ethernet cfm configuration-errors
I - Wrong interval
V - Wrong Level
T - Timed out (archived)
M - Missing (cross-check)
U - Unexpected (cross-check)
Dir MEPs/Err RD Defects AIS
Up
0/0
N
A
Dir MEPs/Err RD Defects AIS
Up
3/2
Y
RPC
Dir MEPs/Err RD Defects AIS
Up
0/0
N
A
Dir MEPs/Err RD Defects AIS
Up
3/2
Y
RPC
Configuring Ethernet OAM
Type
ID
MAC
Dn MEP
2 44:55:66
MIP
55:66:77
Dn MEP
5 66:77:88!
L7
L6

Advertisement