Table 5‑3. Terminal screw torque
Screw
Minimum NM (pound-
inches)
M2
0.2 (1.9)
M6
3.0 (26.1)
M8
11.5 (101.8)
M10
22.0 (194.7)
M12
38.0 (336.3)

Connection Diagrams

    
  DANGER:
RISK OF DEATH OR BODILY INJURY. Disconnect and lockout/tagout all
sources of input power before working on this unit or anything connected to
it.
  DANGER:
RISQUE DE MORT OU DE BLESSURES CORPORELLES. Débrancher et
verrouiller/étiqueter toutes les sources de puissance d'entrée avant de
travailler sur cette unité ou sur tout élément qui y est raccordé.
57010148-00B
Model
Rated NM (pound-
inches)
0.25 (2.2)
4.4 (38.9)
17.0 (150.5)
33.0 (292.1)
56.0 (495.6)
Installation, Setup, and Operation
Thyro-PX® Power Controller
Connector
Screw
M8
M6
M8
M10
M12
Torque
Maximum NM (pound-
inches)
0.3 (2.5)
5.9 (52.2)
22.5 (199.1)
44 (389.4)
75 (663.8)
Protective
Earth screw
M10
M6
M10
M10
M12