A 2-phase or 3-phase Thyro-PX power controller can be configured to operate as a 1-
phase unit controlling two or three zones.
1. Remove the covers from the unit at an ESD safe work space.
2. Disconnect and remove the factory-installed wires connecting A1.X1 to A3.X1
(3-phase only) and A5.X1.
Do not remove the jumpers.
3. Verify that the following jumpers are in place:
a. A1,X1,1 to A1.X1.2.
b. A3,X1,1 to A3.X1.2. (3-phase only).
c. A5,X1,1 to A5.X1.2.
d. A1,X1,4 to A1.X1.5 (2-phase only).
4. Install a jumper between A1.X1.4 and A1.X1.5 (3-phase only).
5. Install a jumper between A3.X1.4 and A3.X1.5 (3-phase only).
6. Install a jumper between A5.X1.4 and A5.X1.5.
7. Connect A1.X1.3 to the reference phase L2, L3, or N.
8. Connect A3.X1.3 to the reference phase L2, L3, or N (3-phase only).
9. Connect A5.X1.3 to the reference phase L2, L3, or N.
10. Connect X51.4 and X51.5 to terminal X51.2.
11. Install the covers.
To convert a 3-phase unit, see
Figure
5-25. The wiring changes are shown in red.