Digital outputs DIGITAL-OUT1 / DIGITAL-OUT2
ASCII: OxMODE
ASCII: OxTRIG
You can combine the following standard pre-programmed functions with the digital outputs
DIGITAL-OUT1 (O1MODE, terminal X3/16) or DIGITAL-OUT2 (O2MODE, terminal X3/17). Change this only
while the amplifier is disabled + reset.
The following level information refers to the output at additional inverting interface terminals (e.g. Phoenix
DEK-REL-24/I/1), see Installation Manual.
High functions:
The presence of the function that is set is indicated by a High signal on the corresponding interface terminal.
Low functions:
The presence of the function that is set is indicated by a Low signal on the corresponding interface terminal.
25-27
Setup Software
ID
Function
0
Off
1
v_act<x
2
v_act>x
3
Mains-RTO
4
Regen off
5
Sw_limit
6
Pos.>x
7
InPos
8
I_act<x
9
I_act>x
10
FError
11
I²t
12
Posreg.1
13
Posreg.2
14
Posreg.3
15
Posreg.4
16
Next-InPos
17
Error/Warn
18
Error
19
DC_Link>x
20
DC_Link<x
21
ENABLE
22
Zero_pulse
23
Reserved
24
Ref_OK
Reserved
28
Posreg. 0
29
Posreg. 5
07/03
Default: 0
Default: 0
Logic
Auxiliary value OxTRIG
-
High
speed (rpm)
High
speed (rpm)
Low
High
High
High
position (increments)
High
High
current (mA)
High
current (mA)
Low
High
High
High
High
High
High
High
High
High
High
High
High
-
High
-
High
High
Screen page "Digital I/O"